Adapter ATS060T- 60W Series best quality
Datasheet-ATS060T-60W-Series.pdf
60 Watt Series Wall Mount adapter Type USA / Japan / Taiwan / Europe – ATS060T from 12 VDC to 48 VDC – IEC/EN/UL 62368-1
Features :
- IEC/EN/UL 62368-1
- 100-240VAC Universal Input
- Regulated Output With Low Ripple Noise
- Safety Agency Requirements and EMI/EMS Certified
- Modified and Custom Design Available
- 1 Year Warranty
Model | O/P Voltage | O/P Current | Watt |
---|---|---|---|
ATS060T-W120□ | 12.0V | 5.00A | 60W |
ATS060T-W150□ | 15.0V | 4.00A | 60W |
ATS060T-W180□ | 18.0V | 3.33A | 60W |
ATS060T-W190□ | 19.0V | 3.15A | 60W |
ATS060T-W240□ | 24.0V | 2.50A | 60W |
ATS060T-W300□ | 30.0V | 2.00A | 60W |
ATS060T-W480□ | 48.0V | 1.25A | 60W |
Input | |||
Voltage | 100-240 VAC | ||
Line Frequency | 50-60Hz | ||
Current | 1.5A Max. | ||
Protection | Internal Primary Current Fuse | ||
Configuration | U for US Plug | ||
E for EU Plug | |||
Output | |||
Load Regulation | ± 5% | ||
Ripple & Noise | 1% Vp-p Max. for Output Voltage @ Full Load | ||
Transient Response | 0.5ms for 50% Load Change Typical | ||
Hold-up Time | 10mS @ Full Load | ||
Protection | Short Circuit Protection/ Over Voltage Protection/ Over Current Protection |
||
Safety Approvals | |||
FOR USA - CB / UL / cUL / FCC / PSE / BSMI / LPS | |||
FOR Europe - CB / CE / LPS | |||
Electrical | |||
Topology | Switching Flyback | ||
Dielectric Withstand | 3000 VAC Primary - Secondary | ||
Leakage Current | 0.25mA | ||
Efficiency | DoE Level VI, ErP Stage 2, CoC Tier 2 | ||
EMC Standards | EN55032 | ||
EN61000-3-2,3 | |||
EN55035 | |||
MTBF | 300,000 Calculated Hours at 25°C, by Telcordia SR-332 | ||
Environmental | |||
Operating Temperature | -20 to +40°C | ||
Storage Temperature | -20 to +80°C | ||
Relative Humidity | Operating: 20 to 80% RH | ||
Storage: 10 to 90% RH | |||
Cooling | Natural Convection Cooling | ||
Mechanical | |||
Case Dimensions | U - L 95 x W 35.5 x H 77 (mm) | ||
E - L 95 x W 35.5 x H 92 (mm) | |||
Weight | 275g (Ref.) |