Adapter ATS065A1- 65W Series best quality

PDF DATASHEET   Datasheet-ATS065A1-65W-Series.pdf

65 Watt Series Desktop Type – ATS065A1 from 12 VDC to 56 VDC – IEC/EN/UL 62368-1

Features :

  • IEC/EN/UL 62368-1
  • 100-240VAC Universal Input
  • Regulated Output With Low Ripple Noise
  • Safety Agency Requirements and EMI/EMS Certified
  • Modified and Custom Design Available
  • 1 Year Warranty
ModelO/P VoltageO/P CurrentWatt
ATS065A1-□12012.0V5.00A60W
ATS065A1-□15015.0V4.34A65W
ATS065A1-□16016.0V4.07A65W
ATS065A1-□18018.0V3.62A65W
ATS065A1-□19019.0V3.43A65W
ATS065A1-□24024.0V2.71A65W
ATS065A1-□48048.0V1.36A65W
ATS065A1-□56056.0V1.17A65W
Input
Voltage100 - 240VAC
Line Frequency50-60Hz
Current1.4A Max.
ProtectionInternal Primary Current Fuse
ConfigurationIEC60320/ C6, C8, C14
Output
Load Regulation± 5% (Typical)
Ripple & Noise1% Vp-p Max. for Output Voltage @ Full Load
Transient Response0.5mS for 50% Load Change Typical
Holdup Time10mS @ Full Load
ProtectionShort Circuit Protection/ Over Voltage Protection/ Over Current
Protection
Safety Approvals
 CB / UL / cUL / FCC / GS / CE / CCC / PSE / BSMI / LPS
Electrical
TopologySwitching Flyback
Dielectric Withstand3000 VAC Primary – Secondary
Leakage Current0.25mA @ 2 Pin / 3.5mA @ 3 Pin
EfficiencyDoE Level VI, ErP Stage 2
EMC StandardsEN55032
EN61000-3-2,3
EN55035
MTBF300,000 Calculated Hours at 25°C, by Telcordia SR-332
Environmental
Operating Temperature-20 to +40°C
Storage Temperature-20 to +80°C
Relative HumidityOperating: 20 to 80% RH
Storage: 10 to 90% RH
CoolingNatural Convection Cooling
Mechanical
Case DimensionL 115 x W 48.5 x H 31.6 (mm)
Weight220g (Ref.)
E - L 95 x W 35.5 x H 92 (mm)
Weight275g (Ref.)