Adapter ATS024T- Desktop Type 24W Series best quality

PDF DATASHEET   Datasheet-ATS024T-24W-Series.pdf

24 Watt Series Desktop Type – ATS024T from 5 VDC to 48 VDC – IEC/EN/UL 62368-1

Features :

  • IEC/EN/UL 62368-1
  • 100-240VAC Universal Input
  • Regulated Output With Low Ripple Noise
  • Safety Agency Requirements and EMI/EMS Certified
  • Modified and Custom Design Available
  • 1 Year Warranty
Model O/P Voltage O/P Current Watt
ATS024T-□050   5.0V 4.0A 20.00W
ATS024T-□060   5.9V 3.5A 20.65W
ATS024T-□061   5.9V 4.0A 23.60W
ATS024T-□070   7.0V 3.0A 21.00W
ATS024T-□075   7.5V 3.0A 22.50W
ATS024T-□090   9.0V 2.5A 22.50W
ATS024T-□120 12.0V 2.0A 24.00W
ATS024T-□150 15.0V 1.6A 24.00W
ATS024T-□240 24.0V 1.0A 24.00W
ATS024T-□480 48.0V 0.5A 24.00W
Input
Voltage 100-240 VAC
Line Frequency 50-60Hz
Current 0.58A Max.
Protection Internal Primary Current Fuse
Configuration IEC60320/ C6, C8, C14
Output
Load Regulation ± 5% (Typical)
Ripple & Noise 2% Vp-p Max. for Output Voltage @ Full Load
Transient Response 0.5mS for 50% Load Change Typical
Hold-up Time 10mS @ Full Load
Protection Short Circuit Protection/ Over Voltage Protection/ Over Current
Protection
Safety Approvals
 CB / UL / cUL / FCC / GS / CE / PSE / BSMI / CCC / RCM / LPS
Electrical
Topology Switchig Flyback
Dielectric Withstand 3000 VAC Primary - Secondary
Leakage Current 0.25mA @ 2Pin / 3.5mA @ 3Pin
Efficiency DoE Level VI, ErP Stage 2, CoC Tier 2
EMC Standards EN55032
EN61000-3-2,3
EN55035
MTBF 300,000 Calculated Hours at 25°C, by Telcordia SR-332
Environmental
Operaturing Temperature -20 to +40°C
Storage Temperature -20 to + 80°C
Relative Humidity Operating: 20 to 80% RH
Storage: 10 to 90% RH
Cooling Natural Convection Cooling
Mechanical
Case Dimension C6 & C14 : L 100 x W 50 x H 33 (mm)
C8 : L 88 x W 50 x H 34 (mm)
Weight 166g (Ref.)